M series gas-liquid booster pump

2013-11-19-10-42-25.gif  

M series gas-liquid booster pump adopts built-in single gas control two-position four-way valve to realize the automatic reciprocating motion of the pump. This series of products are designed and manufactured by our company after digesting and absorbing foreign similar products in accordance with Chinese standards. The air drive part is all made of aluminum alloy and oxidized. The pump head can choose carbon steel or stainless steel according to different media.
This series of products have a driving piston diameter of 80mm and an air pressure of ≤8bar. This series of pumps has the following characteristics:
◆ Light weight and easy to carry ◆ Large flow and wide pressure range ◆ Easy to control, both manual control and automatic control can be realized
◆ Applicable to most liquids ◆ No electricity required, can be used in dangerous places ◆ Easy maintenance

model

Boost ratio

Outlet pressure

flow

L / min

Connection size

net weight

Kg

bar

psi

Drive port

Entrance

Export

M4

4: 1

32

464

15.36

G3 / 8

NPT 1

NPT 1/2

4.8

M10

10: 1

80

1160

7.15

G3 / 8

NPT 3/4

NPT 1/2

4.3

M16

16: 1

128

1856

4.59

G3 / 8

NPT 1/2

NPT 1/2

4.2

M30

30: 1

240

3480

2.53

G3 / 8

NPT 1/2

NPT 3/8

4.2

M44

44: 1

352

5104

1.41

G3 / 8

NPT 3/8

NPT 3/8

4.1

M64

64: 1

512

7424

0.95

G3 / 8

NPT 3/8

NPT 3/8

4.1

M100

100: 1

800

11600

0.64

G3 / 8

NPT 3/8

NPT 3/8

4.1

M170

170: 1

1360

19720

0.37

G3 / 8

NPT 3/8

M14 * 1.5

4.1


* Boost ratio is drive piston area / hydraulic plunger area

* The outlet pressure is the static outlet pressure (estimated value and maximum allowable value) when the air-driven pressure is 8 bar (116 psi)
* The flow rate is the approximate flow rate of the liquid pump when the air-driven pressure is 6 bar (87 psi) and the outlet pressure is 0
* Minimum driving pressure required for liquid pump operation is 3bar (43.5psi), according to a specific pressure ratio to achieve a certain output pressure

MD series gas-liquid booster pump

2014-1-10-15-39-42.gif

MD series pumps are single-drive double-acting pumps, which have the same characteristics as the M series pumps, but compared with the same specifications of the M series pumps, the pulses are smaller and the flow rate is higher than M
Series single-acting pumps increase by 50%.



model

Boost ratio

Outlet pressure

flow

L / min

Connection size

net weight

Kg

bar

psi

Drive port

Entrance

Export

MD30

30: 1

240

3480

4.09

G3 / 8

NPT 1/2


NPT 3/8


5.1

MD44

44: 1

352

5104

2.42

G3 / 8

NPT 3/8


NPT 3/8


5.1

MD64

64: 1

512

7424

1.68

G3 / 8

NPT 3/8


NPT 3/8


5.1

MD100

100: 1

800

11600

1.01

G3 / 8

NPT 3/8


NPT 3/8


5.1

MD170

170: 1

1360

19720

0.59

G3 / 8

NPT 3/8


M14 * 1.5

5.1


* Boost ratio is drive piston area / hydraulic plunger area
* The outlet pressure is the static outlet pressure (estimated value and maximum allowable value) when the air driven pressure is 8 bar (116 psi)
* The flow rate is the approximate flow rate of the liquid pump when the air-driven pressure is 6 bar (87 psi) and the outlet pressure is 0
* Minimum driving pressure required for liquid pump operation is 3bar (43.5psi), according to a specific pressure ratio to achieve a certain output pressure



M **-2 series gas-liquid booster pump


2013-11-19-10-45-18.gif

The M **-2 series pump is a single-acting double-drive head booster pump. Compared with the M-series pump, it can generate double output pressure at the same air driving pressure.

M **-3 series gas-liquid booster pump


2013-11-19-10-42-25.gif

  The M **-3 series pump is a single-acting three-drive head booster pump. Compared with the M series pump, it can generate 3 times the output pressure under the same air driving pressure.

model

Boost ratio

Outlet pressure

flow

L / min

Connection size

net weight

Kg

bar

psi

Drive port

Entrance

Export

M100-2

200: 1

1600

23200

0.41

G3 / 8

NPT 1/4

M14 * 1.5

6.1

M170-2

340: 1

2720

39440

0.23

G3 / 8

NPT 1/4


M14 * 1.5

6.1

M100-3

300: 1

2400

34800

0.26

G3 / 8

NPT 1/4


M14 * 1.5

7.1

M170-3

510: 1

4080

59160

0.13

G3 / 8

NPT 1/4


M14 * 1.5

7.1


* Boost ratio is drive piston area / hydraulic plunger area
* The outlet pressure is the static outlet pressure (estimated value and maximum allowable value) when the air-driven pressure is 8 bar (116 psi)
* The flow rate is the approximate flow rate of the liquid pump when the air-driven pressure is 6 bar (87 psi) and the outlet pressure is 0
* Minimum driving pressure required for liquid pump operation is 3bar (43.5psi), according to a specific pressure ratio to achieve a certain output pressure